{"id":267,"date":"2026-05-05T13:30:45","date_gmt":"2026-05-05T05:30:45","guid":{"rendered":"https:\/\/www.bct-industry.com\/?page_id=267"},"modified":"2026-05-06T16:29:40","modified_gmt":"2026-05-06T08:29:40","slug":"single-wavelength-x-ray-fluorescence-spectrometer","status":"publish","type":"page","link":"https:\/\/www.bct-industry.com\/index.php\/single-wavelength-x-ray-fluorescence-spectrometer\/","title":{"rendered":"SINGLE WAVE LENGHT X-RAY FLUORESCENCE SPECTROMETER"},"content":{"rendered":"\n<div class=\"wp-block-cover alignfull is-light has-contrast-color has-text-color has-link-color wp-elements-7ebffb6d4fe444e8d595c11eca169621\" style=\"margin-top:0;margin-bottom:0;padding-top:var(--wp--preset--spacing--60);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--60);padding-left:var(--wp--preset--spacing--50)\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-base-background-color has-background-dim-100 has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-constrained wp-container-core-cover-is-layout-e880b668 wp-block-cover-is-layout-constrained\"><div class=\"alignwide-wrap\" data-block=\"columns\">\n<div class=\"wp-block-columns alignwide\">\n<div class=\"wp-block-column\" style=\"flex-basis:65%\">\n<div class=\"wp-block-group is-vertical is-content-justification-stretch is-layout-flex wp-container-core-group-is-layout-fb128502 wp-block-group-is-layout-flex\">\n<p class=\"is-style-text-subtitle wp-block-paragraph\"><strong>Single Wavelength X-ray Fluorescence Spectrometer<\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading has-text-align-left\" style=\"font-size:22rem;font-style:normal;font-weight:300;letter-spacing:-0.03em;line-height:1.4\"><strong>x-<\/strong>Ray<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Specification Analysis<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Model: MEDX260<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Detected Elements: Chlorine (Cl), Sulfur (S)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Detection Limits:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Chlorine (Cl): \u2264 0.1 mg\/kg<\/li>\n\n\n\n<li>Sulfur (S): \u2264 0.2 mg\/kg<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Measurable Mass Fraction Ranges (Variable):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Chlorine (Cl): 0.1 mg\/kg \u2013 1.0 %<\/li>\n\n\n\n<li>Sulfur (S): 0.2 mg\/kg \u2013 5.0 %<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Spectral Separation Method: Crystal diffraction<br>X\u2011ray Optical System: Johansson geometry<br>Analyzing Crystal: Pyrolytic graphite C(002)<br>X\u2011ray Tube: Chromium or palladium anode<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Measurement Time: Not less than 8 minutes for duplicate tests on one sample<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Application: Suitable for gases or liquids<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Analytical Characteristics<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Elements Determined: Cl (Chlorine), S (Sulfur)<\/li>\n\n\n\n<li>Detection Limit:- Chlorine: \u2264 0.1 mg\/kg<\/li>\n\n\n\n<li>Sulfur: \u2264 0.2 mg\/kg<\/li>\n\n\n\n<li>Measurement Range of Mass Fraction (Variable):- Cl (Chlorine): 0.1 mg\/kg ~ 1.0 %<\/li>\n\n\n\n<li>S (Sulfur): 0.2 mg\/kg ~ 5.0 %<\/li>\n\n\n\n<li>Spectral Separation Method: Crystal diffraction<\/li>\n\n\n\n<li>X-ray Optical System: Johansson geometry<\/li>\n\n\n\n<li>Analyzing Crystal: Pyrolytic graphite C(002)<\/li>\n\n\n\n<li>X-ray Tube: Cr or Pd anode<\/li>\n\n\n\n<li>Measurement Time for Two Parallel Samples (1 Sample): \u2265 8 minutes<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Technical Specifications<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Sample Introduction Device: Side-loading type, 3-position (automatic)<\/li>\n\n\n\n<li>Sample Cup: Diameter \u2264 32 mm, Volume \u2264 8 cm\u00b3, with vent structure<\/li>\n\n\n\n<li>X-ray Tube Power: Max. 200 W<\/li>\n\n\n\n<li>Interfaces: Built-in display &amp; thermal printer; USB port for PC connection<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Dimensions &amp; Weight (Max.)<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Spectrometer Main Unit: 530\u00d7480\u00d7340 mm, 40 kg<\/li>\n\n\n\n<li>Vacuum Pump: 350\u00d7250\u00d7400 mm, 20 kg<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Power Supply<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>220 V, ~50 Hz, 750 W<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Standard Delivery List<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Vacuum spectrometer main unit: 1 pc<\/li>\n\n\n\n<li>Vacuum pump: 1 pc<\/li>\n\n\n\n<li>Signal indicator light: 1 pc<\/li>\n\n\n\n<li>Vacuum hose: 1 pc<\/li>\n\n\n\n<li>USB cable (USB A &#8211; USB B): 1 pc<\/li>\n\n\n\n<li>Keys: 2 pcs<\/li>\n\n\n\n<li>Uninterruptible power supply (1000 VA): 1 pc<\/li>\n\n\n\n<li>Software USB flash drive: 1 pc<\/li>\n\n\n\n<li>Funnel: 1 pc<\/li>\n\n\n\n<li>Fuse 5A (d5\u00d720): 3 pcs<\/li>\n\n\n\n<li>Antifreeze (1 kg\/bottle): 1 bottle<\/li>\n\n\n\n<li>Calibration sample set for mass fraction of chlorine and bismuth in mineral oil: 1 set<br>(including 6 calibration samples:<br>GO-1 \u2014 600 ml,<br>GO-2 \u2014 100 ml,<br>GO-3 \u2014 400 ml,<br>GO-4 \u2014 100 ml,<br>GO-5 \u2014 100 ml,<br>GO-6 \u2014 100 ml)<\/li>\n\n\n\n<li>Organometallic bismuth compound 5000 ppm: 5 bottles (50 g each)<\/li>\n\n\n\n<li>Disposable Pasteur pipettes: 200 pcs<\/li>\n\n\n\n<li>PET film (100 m\/roll): 5 rolls<\/li>\n\n\n\n<li>Ventilated sample cups with air holes (100 pcs\/pack): 2 packs<\/li>\n\n\n\n<li>Sulfur standard sample 600 ppm (0.06%): 1 pc<\/li>\n\n\n\n<li>Rubber suction bulb: 1 pc<\/li>\n\n\n\n<li>Thermal printer paper, 57 mm (24 m\/roll): 5 rolls<\/li>\n\n\n\n<li>Silicone drain hose 8.0 \u00d7 2: 1 pc<\/li>\n\n\n\n<li>Power filter: 1 pc<\/li>\n\n\n\n<li>Push rod: 1 pc<\/li>\n\n\n\n<li>KCl calibration sample: 1 pc<\/li>\n\n\n\n<li>Entrance slit (with ring): 1 set<\/li>\n\n\n\n<li>Sample cup removal tool: 1 pc<\/li>\n\n\n\n<li>Wavelength calibration sample (Range 1): 1 pc<\/li>\n\n\n\n<li>Wavelength calibration sample (Range 2): 1 pc<\/li>\n\n\n\n<li>Sample cup holder: 1 pc<\/li>\n<\/ul>\n\n\n\n<p class=\"is-style-text-subtitle wp-block-paragraph\">No national or transnational standards applicable.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column\" style=\"flex-basis:35%\">\n<div class=\"wp-block-group is-vertical is-content-justification-stretch is-nowrap is-layout-flex wp-container-core-group-is-layout-d1861144 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"557\" src=\"http:\/\/www.bct-industry.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260505132915_468_160.jpg\" alt=\"\" class=\"wp-image-268\" style=\"aspect-ratio:3\/4;object-fit:cover\" srcset=\"https:\/\/www.bct-industry.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260505132915_468_160.jpg 500w, https:\/\/www.bct-industry.com\/wp-content\/uploads\/2026\/05\/\u5fae\u4fe1\u56fe\u7247_20260505132915_468_160-269x300.jpg 269w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-right has-x-large-font-size wp-block-paragraph\" style=\"line-height:1.2\"><a href=\"#\">Instagram<\/a><br><a href=\"#\">\u94fe\u63a5<\/a><br><a href=\"#\">\u73b0\u5728<\/a><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<div class=\"link-more\"><a href=\"https:\/\/www.bct-industry.com\/index.php\/single-wavelength-x-ray-fluorescence-spectrometer\/\" class=\"more-link\">\u7ee7\u7eed\u9605\u8bfb<span class=\"screen-reader-text\"> &ldquo;SINGLE WAVE LENGHT X-RAY FLUORESCENCE SPECTROMETER&rdquo;<\/span> &hellip;<\/a><\/div>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-267","page","type-page","status-publish","hentry","entry"],"_links":{"self":[{"href":"https:\/\/www.bct-industry.com\/index.php\/wp-json\/wp\/v2\/pages\/267","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bct-industry.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.bct-industry.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.bct-industry.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bct-industry.com\/index.php\/wp-json\/wp\/v2\/comments?post=267"}],"version-history":[{"count":4,"href":"https:\/\/www.bct-industry.com\/index.php\/wp-json\/wp\/v2\/pages\/267\/revisions"}],"predecessor-version":[{"id":366,"href":"https:\/\/www.bct-industry.com\/index.php\/wp-json\/wp\/v2\/pages\/267\/revisions\/366"}],"wp:attachment":[{"href":"https:\/\/www.bct-industry.com\/index.php\/wp-json\/wp\/v2\/media?parent=267"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}